📻 Meshtastic Firmware Update Guide
This guide provides instructions for updating firmware on various Meshtastic-compatible devices.
📑 Table of Contents
- Prerequisites
- Using the Web Flasher
- Updating RAK19007/19003 Nodes
- Updating Heltec Nodes
- Updating Seedstudio T1000E
- Over-the-Air (OTA) Updates for RAK Nodes (Advanced Users Only)
📋 Prerequisites
Before beginning any firmware update, ensure you have:
- 🔌 A USB data cable (not just a charging cable)
- 🌐 For web flasher: A compatible browser (Chrome or Edge recommended)
- 💻 For CLI updates: The latest version of the Meshtastic CLI installed
- 📥 The appropriate firmware file for your device from the Meshtastic releases page
- 🐍 For wired updates with CLI: Python 3.x and esptool
- 📱 For OTA updates: An Android device with Bluetooth capabilities
🌐 Using the Web Flasher
The easiest way to update firmware on most Meshtastic devices is using the browser-based flasher tool:
- 🔌 Connect your device to your computer using a USB cable
- 🖥️ Visit flasher.meshtastic.org in a WebUSB compatible browser (Chrome or Edge recommended)
- 📋 Select your device type from the dropdown menu:
- 🔍 Auto-detect option: The web flasher can automatically detect many common device types - look for “Auto” or “Auto-detect” at the top of the device selection dropdown
- If auto-detection doesn’t work, manually select your specific device model
- 🔄 Choose the firmware version you want to install:
- ✅ Select “Release” for stable firmware
- 🧪 Select “Alpha” for testing new features (may be unstable)
- 🎛️ Select “Custom” if you have a specific firmware file to upload
- 🔗 Click “Connect” and select your device from the popup dialog:
- On Windows: You’ll see your device listed with a COM port (e.g., “USB Serial Device (COM3)”)
- On macOS: You’ll see your device with a /dev identifier (e.g., “usbmodem1101”)
- On Linux: You’ll see your device with a /dev/ttyUSB or /dev/ttyACM identifier
- Select the appropriate device from this list
- ⚡ Click “Flash” to begin the update process:
- The screen will show detailed progress information
- 🔄 DFU Mode Prompt: Some devices may need to enter Device Firmware Update (DFU) mode during flashing
- If prompted to enter DFU mode, follow the on-screen instructions which typically involve:
- Pressing and holding specific button combinations on your device
- For most ESP32 devices: Hold the BOOT button while pressing and releasing RESET
- The web flasher will display specific instructions for your device model
- Once in DFU mode, the flashing process will continue automatically
- ⏳ Wait for the process to complete - you’ll see a progress bar and log messages
- 🎉 Once finished, your device will automatically reboot with the new firmware
Note: The web flasher requires a browser that supports WebUSB, which is currently only Chrome, Edge, and other Chromium-based browsers. Firefox and Safari are not supported.
✨ Advantages of the Web Flasher:
- 📥 No software installation required
- 🔍 Auto-detection of device types
- 🙂 User-friendly interface
- 💻 Works on Windows, macOS, Linux, and ChromeOS
- 🤖 Automatically handles bootloader mode for many devices
- 📱 Interactive guidance for entering DFU mode when needed
** Video: **
📡 Updating RAK19007/19003 Nodes
The RAK19007 and RAK19003 can be updated using the following method:
-
🔌 Connect your RAK device to your computer using a USB cable
-
🔍 Identify the correct serial port:
- Windows: Check Device Manager under Ports (COM & LPT)
- macOS: Run
ls /dev/cu.*
in Terminal - Linux: Run
ls /dev/ttyUSB*
in Terminal
-
🔄 Put the device in bootloader mode:
- Press and hold the BOOT button
- Press and release the RESET button
- Release the BOOT button
-
⚡ Flash the firmware using Meshtastic CLI:
meshtastic --device [PORT] --flash [PATH_TO_FIRMWARE]
Replace [PORT]
with your device’s serial port (e.g., COM3 on Windows or /dev/ttyUSB0 on Linux) and [PATH_TO_FIRMWARE]
with the path to your downloaded firmware file.
Alternatively, you can use esptool directly:
esptool.py --port [PORT] --baud 921600 write_flash 0x10000 [PATH_TO_FIRMWARE]
- 🔄 After flashing is complete, press the RESET button to restart the device with the new firmware.
Note: The Web Flasher method described earlier is often easier and recommended for most users updating RAK devices.
📟 Updating Heltec Nodes
Heltec devices (like the Heltec WiFi LoRa 32 V2) can be updated with these steps:
-
🔌 Connect your Heltec device to your computer via USB
-
🔍 Identify the serial port as described in the RAK section above
-
🔄 Put the device in bootloader mode:
- Press and hold both the PROG and RESET buttons
- Release the RESET button
- Release the PROG button
-
⚡ Flash the firmware using Meshtastic CLI:
meshtastic --device [PORT] --flash [PATH_TO_FIRMWARE]
Alternatively, use esptool:
esptool.py --chip esp32 --port [PORT] --baud 921600 write_flash 0x10000 [PATH_TO_FIRMWARE]
- 🔄 Press the RESET button after flashing completes.
🛰️ Updating Seedstudio T1000E
The Seedstudio T1000E follows a similar update process:
- 🔌 Connect the T1000E to your computer via USB
- 🔍 Identify the serial port
- 🔄 Enter bootloader mode (consult your device documentation for the exact button combination)
- ⚡ Flash the firmware using the Meshtastic CLI:
meshtastic --device [PORT] --flash [PATH_TO_FIRMWARE]
- 🔄 After flashing completes, reset the device.
For more detailed instructions, visit the Get Started with T1000-E Tracker
📱 Over-the-Air (OTA) Updates for RAK Nodes
⚠️ ADVANCED USERS ONLY: This procedure requires technical knowledge and carries risks including potential device bricking if interrupted. Beginners should use the Web Flasher method.
RAK devices with the RAK4631 chipset (nRF52840-based) can be updated over Bluetooth using an Android device. This method is perfect for nodes installed in hard-to-reach locations where physical access is difficult.
📲 Using the nRF Device Firmware Update App
-
📥 Install the Required App:
- Install the nRF Device Firmware Update app from the Google Play Store
-
📥 Obtain the Correct Firmware:
- Visit the Meshtastic Github Repository
- For the latest beta: Select the “Meshtastic Firmware…” link at the top
- For older versions: Select the “releases” link below that
- Download the “firmware-nrf52840-(version).zip” file to your computer
- Unzip the file and locate the “firmware-rak4631-(version)-ota.zip” file
- Transfer this file to your Android phone
-
⚙️ Configure nRF DFU App Settings:
- Open the nRF DFU app
- Go to Settings (gear icon)
- Configure the following settings (recommended by Meshtastic developers):
Packets receipt notification: On Number of packets: 5 Reboot time: 5000ms Scan timeout: 10000ms Request high MTU: Off Disable resume: Off Prepare object delay: 500ms Force scanning: Off Keep bond: On External MCU DFU: Off
- These specific settings help ensure a successful update process
-
🔄 Perform the OTA Update:
- Get within Bluetooth range of your RAK node (within 2-3 meters)
- In the nRF DFU app, select the firmware file you transferred to your phone
- The app will scan for available devices
- Select your RAK node from the list of discovered devices
- Click “Start” to begin the update process
-
⏳ Update Process:
- Keep your Android device near the RAK node during the entire update
- The process may take 5-10 minutes to complete
- Do not close the app or let your phone screen turn off
- The app will display progress information during the update
- Once complete, the device will automatically reboot with the new firmware
⚠️ Important Notes for OTA Updates
- 🚨 This process is for advanced users who understand the risks involved
- 🔋 Ensure your RAK device has sufficient battery power (at least 50% recommended)
- 📶 Do not move the Android device away from the RAK node during the update
- ⚠️ Interrupting the update process may render your device unusable
- 📱 Keep your phone screen on during the entire update process
- 🔄 If the update fails, you may need to retry or fall back to the wired update method
- 🌐 This method only works with RAK devices that use the nRF52840 chipset (RAK4631-based nodes)
- 📡 The device may show as “Offline” in your mesh network during the update process
⚠️ Disclaimer: Use OTA updates at your own risk. While this method has worked for many users, we cannot guarantee it will work in all situations. If your device is mission-critical or difficult to physically access should something go wrong, consider using the more reliable wired update methods described earlier in this guide.
🔍 Troubleshooting OTA Updates
- If the update fails to start, try restarting both the node and your phone
- Ensure no other apps are connected to your Meshtastic device during the update
- If you can’t see your device in the scan list, make sure it’s powered on and within range
- For persistent issues, verify you’re using the correct firmware file specifically for OTA updates
- The OTA zip file must be the one specifically prepared for OTA updating, not the regular firmware file
For more detailed instructions, visit the PV Mesh OTA Update Guide
🔧 Troubleshooting
🚨 Common Issues and Solutions
-
🔎 Device Not Detected:
- Try a different USB cable
- Try a different USB port
- Install or update device drivers
-
❌ Flashing Fails:
- Ensure the device is in bootloader mode
- Try a lower baud rate (e.g., 115200 instead of 921600)
- Make sure you’re using the correct firmware for your device
-
📱 OTA Update Fails:
- Ensure your Android device and RAK node are close to each other
- Check that both devices have sufficient battery power
- Try disconnecting and reconnecting before attempting again
- Verify your OTA app settings match the recommended configuration
- Try disabling battery optimization for the update app
- For nRF DFU app: Make sure you’re using the correct -ota.zip file
-
🔄 Device Doesn’t Boot After Update:
- Perform a factory reset by holding the appropriate buttons for your device
- Re-flash using the wired method
-
🌐 Web Flasher Issues:
- Make sure you’re using Chrome or Edge browser
- Try different USB ports or cables
- If the device isn’t recognized, manually put it in bootloader mode
- If prompted to enter DFU mode but can’t get it to work, try manually entering bootloader mode first, then reconnect
- Clear browser cache and try again
- If auto-detection fails, try selecting your device model manually
-
🔄 DFU Mode Issues:
- If your device won’t enter DFU mode, try different button combinations
- Some devices require timing the button presses precisely
- Try disconnecting and reconnecting the USB cable before attempting again
- Check that you’re using a data-capable USB cable, not just a power cable
📚 Additional Resources
- 📖 Official Meshtastic Documentation
- 💻 Meshtastic GitHub Repository
- 👥 Meshtastic Community Forum
- 🌐 Web Flasher Tool
🔄 Last updated: 2025-09-11